DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine

DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine

Brand/Manufacturer: DEVILBISS
Hpfy Stores Save
Authorized Retailer Badge
  • HyGiene Products
  • Non Returnable
  • Prescription required
  • FSA Approved
  • Made in USA

DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine is a travel-sized CPAP machine designed to automatically adjust pressure during the night. The machine uses multiple techniques to track therapy effectiveness including a SD card, bluetooth technology and SmartCode. Its whisper quiet operation of 26.6 dBA is less than the typical sound level of a library. The brightness of the controls and the display can be adjusted independently and have both active and standby brightness settings.

Features

  • DeVilbiss IntelliPAP 2 AutoAdjust Auto CPAP Machine includes:
    - IntelliPAP 2 AutoAdjust Auto CPAP Machine
    - Carrying Case
    - 6 Foot Long 15mm Slim Tubing
    - Filter Cover
    - Reusable Filter
    - Disposable Filter
     SD Card
    - Power Supply
    - Power Cord
    - Manual
  • PureView AutoAdjust Algorithm:
    -
    Unique feature used on the machine to detect advanced apnea events like periodic breathing and flow limitation
    - Understands complex issues, leading to automatic changes in pressure in response to OSA and CSA events
    - Operate between a low and high pressure range, remaining at the lower pressure until an event is detected requiring a higher pressure
  • Large LCD Screen Display:
    -
    Increases the visibility of displayed information and pairs with a knob that is turned and pressed for easy navigation of menus and settings
    - The display can also show regular reminders to change filters and clean equipment, if desired
    - When in standby, the machine will display a clock and also has an alarm clock function
    - On-Screen Data Includes AHI, leak rate and usage information
  • SmartCode Adherence Score
    -
    SmartCode messages begin to display on the screen after the first night of therapy
    - Each code is a uniquely encrypted code holding personal sleep data results
    - SmartCode is intended to help IntelliPAP 2 users become compliant
    - SmartCode Adherence is determined after the machine is used for 30 consecutive days
    - Data can be generated to depict results from 1 Day, 7 Days, 30 Days, 90 Days, a cumulative report
  • Bluetooth Capable Technology
    -
    Enable the Bluetooth feature to begin pairing the IntelliPAP 2 to the SmartLink app
    - The SmartLink Data Management System is designed for use on Apple and Android devices
    - To begin using the app, visit the iTunes App Store or the Google Play Store depending on the device
    - Search DeVilbiss SmartLink to locate the SmartLink app
    - Once the app has been downloaded and the Bluetooth option is turned ON, data will begin streaming from the machine to the handheld device
    - The SmartLink app is compatible with iPhone, iPad or iPod touch running Apple iOS 8 or newer and Android smartphones and tablets running 4.0.3 or newer
  • SmartFlex and Adjustable Rounding
    -
    Designed to decrease pressure during exhalation 1, 2, or 3 cm for a more comfortable breathing pattern during therapy
    - Adjustable rounding allows the user to customize the transition between exhalation to inhalation and inhalation to exhalation
    - The machine settings range from 0 to 5
    - Level 0 represents a direct jump in pressure, while level 5 represents the softest transition
  • Ramp Comfort Feature
    - 
    Designed to gradually increase therapy to the lower pressure of the auto range over a period of time
    - Between 0 to 45 minutes, the machine will slowly raise the pressure to help the user become acclimated to their therapy so they may fall to sleep with ease
    - The ramp button is on top of the machine and to the right of the humidifier symbol
    - Use the button to start or stop ramp
    - Note: If the machines lower pressure of the auto range is 3, ramp will not be available
  • Auto Start / Auto Stop
    -
    Allows the user to begin and finish CPAP therapy without manually pressing a button
    - When enabled, place the mask against the face and begin breathing into the mask to start sleep therapy
    - Likewise, remove the mask when waking to stop sleep therapy
    - The machine is equipped with button to manually control the device
  • NOTE: Prescription can be faxed to 1.203.616.2851 or emailed to prescription@hpfy.com
  • Also Available (Seperately): 
    - DeVilbiss IntelliPAP 2 Heated Humidifier with Pulse Dose Humidification (Code : DV6HHPD)
    - DeVilbiss IntelliPAP 2 Standard Heated Humidifier (Code : DV6HH)
    - DeVilbiss SmartLink 3.0 Software CD (Code : SL3-CD)

More Information

  • Air Supply Port Cover
    -
    When the IntelliPAP 2 machine and humidifier are connected, the air supply port cover folds into the circular crevice located on the back of the IntelliPAP 2 machine
    - If using the IntelliPAP 2 machine without the humidifier, reposition the air supply port cover so it coats the circular opening found on the bottom of the IntelliPAP 2 machine
    Note: The cover must be put back into the opening found on the back of the machine when preparing to reconnect the machine and humidifier
    - If the cover is still protecting the hole on the bottom of the machine, the devices will not fasten
  • Water Chamber Cleaning Tips
    -
    The water chamber for the IntelliPAP 2 Heated Humidifier needs to be cleaned daily
    - The water chamber may be placed in the dishwasher for an occasional cleaning
    - When placed in the dishwasher, the chamber must sit on the top rack
    - For all other daily needs, hand wash the chamber with warm water and mild soap
    - Before cleaning the chamber, the user will need to remove the tank from the humidifier cradle
  • Steps to withdraw the chamber
    -
    Gently press on the chamber release latch which is located at the front of the chamber
    - Slide the chamber out of the cradle
    - Locate and push forward on the chamber disassembly lever which is directly behind the chamber release latch
    - The chamber will open into two halves
  • Instructions for Filling the Water Chamber
    -
    When refilling the water chamber, use distilled water to help prevent mineral build-up
    - The IntelliPAP 2 water chamber has water level indicators located on the sides and top of the chamber
    - Do not surpass the specified markings when refilling the chamber, as it may cause water damage
  • Sealing Gasket Maintenance
    -
    Before each use, examine the sealing gasket surrounding the circumference of the chamber
    - Ensure the gasket has been put back into place after each cleaning

Specification

Particulars Specifications
Dimensions of Machine  6.1"W x 5.9"D x 3.7"H
Power Supply 65W, 100 - 240V, 50/60 Hz
DC Electrical Requirements 11 - 17 VDC, 5.2 Amps
Pressure Range 3 - 20 cm H2O
Operating Temperature Range 41°F to 104°F (5°C to 40°C)
Operating Humidity Range 15% to 93% RH non-condensing
Operating Atmospheric Conditions 1060 hPa - 700 hPa (1,400 ft below sea level to 9,800 feet)
Storage and Transportation Temperature Range -13°F to 158°F
Storage and Transportation Humidity Range 15% to 93% RH non-condensing
Sound Pressure Level <26.6 dBA
Sound Power Level <34.6 dBA
Carry Bag Dimensions 11"L x 5.5"W x 8.5"H

Warranty

3 Year Warranty

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopnebulizer.com

Close