Somnetics Transcend Auto Mini CPAP Machine With EZEX
Somnetics Transcend Auto Mini CPAP Machine With EZEX

Somnetics Transcend Auto Mini CPAP Machine With EZEX

Brand/Manufacturer: SOMNETICS INTERNATIONAL, INC
Save
Authorized Retailer Badge

Somnetics Transcend Auto Mini CPAP Machine With EZEX is a premium auto-adjusting device with expiratory relief technology which provides pressure relief on exhalation for more breathing comfort. The Auto continually monitors your breathing to adapt to your changing therapy needs. The Transcend Auto provides positive airway pressure to users in the range of 4 to 20 cmH2O as prescribed by the clinician. The therapeutic pressure is automatically titrated by the device. It is fully-featured with a therapy range of 4-20 cmH2O, ramp feature, automatic altitude adjustment up to 8,000 feet, automatic voltage conversion and they store up to 13 months of compliance.

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

Buy this product and earn 26.5 Reward Dollars.

Item# 503065

  • ORDERING DETAILS
  • CPAP Machine
  • Optional Accessories
  • Total: $800.65
    Total: $529.99
Total: $800.65
Total: $529.99

Features

  • Somnetics Transcend Auto Mini CPAP Machine With EZEX includes:
    - Transcend Auto
    - Standard 6-foot hose (Note: not compatible with optional H6B or H9M Waterless Humidification Systems)
    - Universal hose adapter
    - Multi-plug universal power supply (PSA2)
    - Changeable plug pack
    - Transcend Travel bag
    - Transcend Auto Quick Guide
    - USB Cable
  • Buttons and LED lights facilitate control and provide operational feedback
  • Engineered with a vibration-free blower, Transcend only makes 26.6 dBA of sound
  • From your desktop, up to the cloud, TranSync makes it easy for CPAP users to track and share their therapy data
  • An external power source connects to the Transcend Auto to supply power to the device
  • Innovative solutions that fit active lifestyle
  • Smallest, lightest, most portable CPAP
  • Easy to pack and carry for travel (weighs less than a pound!)
  • Flexibility and freedom for patients
  • FAA compliant for use onboard aircraft
  • Automatic pressure compensation to 8,000 feet
  • Perfect choice for patients who no longer wants to be tied to their bed stand
  • Power options provide backup power during storms and brown outs for uninterrupted therapy
  • Perfect for use in remote locations where power is unavailable
  • Transcend has two battery options, solar battery charger, and a DC mobile power adaptor, giving unmatched power options that support therapy on the go
  • Solar charger eliminates concerns about available power, Go anywhere with comfort of therapy
  • Mobile power adaptor for cars, trucks, boats or RVs
  • Universal AC power supply automatically converts voltage outside the US
  • Compliance Reporting:
    - AHI and leak detection
    - 13 months of data storage on-device
    - Downloadable via mini-USB cord
    - Email-capable compliance reporting
    - TranSync Wireless compliance reporting
  • Control panel :
    - The Transcend Auto control panel has two pushbuttons used to activate the blower and the pressure ramp feature. There are also two LED lights, including a green LED for indicating normal operational modes and a yellow LED that indicates fault conditions.
  • Power connection jack:
    - The power jack accepts the barrel plug of the output cable from a DC power source to operate the Transcend Auto. A variety of power sources may be used to power the Transcend Auto. AC to DC converting power supply is provided with your device and should be used when powering the device by line (wall outlet) power.
  • A mini-AB USB port:
    - Provided for direct data exchange between the Transcend Auto and a computer via a USB data cable. This interface allows the clinician to configure the Transcend Auto for prescription pressure, ramp settings, and Auto settings and provides access to therapy compliance information that can be viewed by the user and emailed to the clinician
  • Air Inlet Filter:
    - During therapy operation, ambient air is drawn into the Transcend Auto through an Air Inlet Filter. The Filter Media should be cleaned at least weekly according to the instructions provided in this User Manual and replaced minimally after 6 months of use. Replace more frequently as desired
  • Transcend Auto provides positive airway pressure for treatment of obstructive sleep apnea (OSA) in adults weighing over 66 pounds (30 kg)
  • Device is intended for home and hospital/institutional use
  • Compatible with all Transcend accessories (not included):
    Transcend Heated Humidifier
    - Transcend Mobile Power Adapter
    - Transcend P4 Battery
    - Transcend P8 Battery
    - Transcend Base Station
    - Transcend LCD Programming Base Station
    - Transcend Portable Solar Battery Charger
  • Click Here For User Manual
  • Click Here For Quick Guide

More Information

  • Caring for your Transcend Auto and components:
    Cleaning the Exterior :
    - Unplug the power supply prior to cleaning and disconnect the device from power cords.
    - Mix a solution of 5% mild liquid detergent in distilled water (1.6 fl oz liquid detergent per quart of distilled water).
    - Mild detergent should contain biodegradable anionic surfactants and no phosphate.
    - Submerge a lint-free cotton cloth into the detergent solution.
    - Wring excess water from the cloth then wipe the exterior of the Transcend Auto device for approximately 20 seconds using a gentle, back and forth wiping motion from the front to back of the device.
    - Apply firm pressure and ensure contact with all accessible contact surfaces to adequately remove soil buildup.
    - Rinse the cloth in clear water to remove the residual cleaning solution.
    - Wring excess water from the cloth then wipe the Transcend Auto using a gentle front to back wiping motion to remove any detergent solution remaining on its surface.
    - Wipe the device with a dry, lint-free cotton cloth until the device is fully dry
    - Product Periodic Cleaning Cycle: 2x/Month
    - Product Service Life 5-Year
    Cleaning the Filter Media and Filter Frame:
    - Clean the foam Filter Media and Filter Frame at least once per week.
    - Begin by removing the Filter Media and Filter Frame from the device (see Replacing the Filter Media for instructions on filter removal and replacement).
    - Mix a solution of 5% mild liquid detergent in distilled water (1.6 fl oz liquid detergent per quart of distilled water).
    - Mild detergent should contain biodegradable anionic surfactants and no phosphate.
    - Fully immerse the Filter Frame in the detergent solution.
    - While immersed, thoroughly wipe each surface of the Filter Frame with a lint-free cotton cloth.
    - Apply firm pressure and ensure contact with all accessible contact surfaces to adequately remove soil buildup.
    - Rinse the Filter Frame by immersing in distilled water and gently moving it forwards and backward for approximately 10 seconds.
    - Use a clean, dry, lint-free cotton cloth to dry all surfaces of the Filter Frame. - To clean the Filter Media, first, submerge a lint-free cotton cloth into the cleaning solution.
    - Wipe the Filter Media with a cloth to remove any visible residue. Wipe all surfaces for a minimum of 10 seconds.
    - Rinse the cotton cloth in distilled water to remove the residual cleaning solution. - Wring excess water from the cloth then wipe all surfaces of the Filter Media to remove any cleaning solution remaining on its surface.
    - Dry surfaces by wiping with a dry, lint-free cotton cloth.
    - Allow the Filter Media to air dry at room temperature for approximately 30-60 minutes before reassembly. Drying time will depend on ambient conditions. - Reconnect the Filter Media and filter frame to the Transcend Auto.
    Cleaning for Multiple Users:
    - Unplug the power supply prior to cleaning.
    - Remove and discard the bacterial/viral filter.
    - Remove and discard the used air supply tube.
    - Follow instructions for cleaning the exterior of the device as noted in Cleaning the Exterior (above).
    - Apply a new bacterial/viral filter to the Universal Hose Adapter of the Transcend Auto and attach a new air supply tube before providing the device to a new user.
  • Precautions:
    - When using a computer with Transcend Auto. Do not plug any devices into the Transcend USB port other than a computer that is compliant with 60950-1 safety standards.
    - Attaching any other device to the Transcend USB port may damage Transcend and may not be safe for the user. In order to reduce the risk of leakage currents, use an isolation transformer which is IEC 60601-1 approved to power your computer.
    - Do not plug your computer or your Transcend into a multiple portable socket outlet (i.e. power strip).
    - When using your computer follow the manufacturers cleaning instructions and conducting preventative maintenance.
    - Do not attach Transcend USB port to your computer during preventative maintenance of your computer.
    - Do not touch your computer any exposed metal on Transcend or on Transcend cables at the same time.
    - Do not touch exposed metal on your computer or exposed metal on connectors or cables.
    - For clinicians, do not simultaneously touch the computer and the patient.
    - Do not use computers that have internal voltages that are accessible without the use of tools in order to gain access to such voltages.
  • Contraindications:
    The Transcend Auto is contraindicated in patients with the following conditions: - Bullous lung disease
    - Pathologically low blood pressure
    - Pneumothorax or pneumomediastinum
    - Pneumocephalus has been reported in some users using nasal PAP
  • Caution:
    - Should be used when prescribing PAP for susceptible users such as those with any of these conditions:
    - Cerebral spinal fluid (CSF) leaks
    - Abnormalities of the cribriform plate
    - A prior history of head trauma
    - Pneumocephalus
    - Indicates the possibility of minor injury or damage to the equipment.
  • Warnings:
    - Do not allow water to enter this device.
    - Transcend Auto should not be exposed to environmental conditions where the system may get wet.
    - This device is not intended for life support.
    - The Transcend Auto must be set up and adjusted by a trained provider before being used for therapy ramp and pressure.
    - The air temperature produced by this device can be as much as 10ºF higher than the temperature of the room.
    - Exercise caution if the room temperature is warmer than 90ºF (32ºC).
    - Do not block or otherwise obstruct the exhalation ports of the interface.
    - This equipment is not suitable for use with oxygen or in the presence of a flammable anesthetic mixture with air or oxygen, or with nitrous oxide.
    - The Transcend Auto is only to be used with the supplied or recommended accessories.
    - Use of accessories not recommended may result in increased electromagnetic emissions or decreased electromagnetic immunity of the PAP system and may be potentially unsafe.
    - The Transcend Auto is not defibrillation proof.
    - Do not attempt to sterilize Transcend Auto.
    - If the device is to be used by multiple patients the main flow bacteria filter should be installed in-line between the device and the breathing circuit tubing to prevent contamination.
    - The device should be used only with masks and connectors recommended by Somnetics or a health care professional.
    - A mask should not be used unless the device is turned on and is properly delivering ramp or therapy pressure.
    - The exhalation port(s) associated with the mask should never be blocked.
    - The device is intended to be used with masks or connectors specifically designed to have exhalation ports to allow continuous flow of air out of the mask.
    - When the device is turned on and functioning properly air flow from the device flushes the exhaled air out through the mask exhalation port.
    - When the device is not operating, however, fresh air will not be provided through the mask and exhaled air may be rebreathed.
    - Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation.
    - Strangulation hazard from the power cord and air tube. These can become wrapped around a neck and STRANGLE.
    - Keep power cord and air tube more than 3 feet from a babys crib and out of babys reach.
    - Keep cord and tube out of childrens reach.
    - Small parts are unlikely to be expelled from the Transcend enclosure, but in the case of severe damage internal components may fragment and create a swallowing or choking hazard if they get out of the enclosure.
    - Discontinue use of the Transcend Auto and contact your physician if respiratory or skin irritations occur.
    - Do not introduce objects into the Transcend Auto air inlet or air outlet.
    - Inspect the power supply for signs of wear or damage before each use.
    - Replace the power cord if necessary. Somnetics recommends replacing the air delivery tubing (hose) after every three months of use.
    - To protect the environment, some parts and accessories of the Transcend Auto, including optional batteries, must be disposed of in accordance with local regulations.
    - Unplug the Transcend Auto before cleaning. Do not submerge the Transcend Auto or power supply in liquid.
    - Prevent water from entering any openings of the device.
    - Do not use harsh or abrasive cleaning agents to clean the device or any components.
    - Do not attempt to sterilize the Transcend Auto.
    - Do not place cleaning materials, such as a cloth or liquid, into the device air inlet or air outlet connector.
    - The air supply tubing, mask assembly, headgear, and bacterial/viral filters should be discarded after each patient use using standard institutional biohazard procedures.
    - No attempt should be made to clean, disinfect, or sterilize these components for multiple users.
    - These components are for single patient use. No attempt should be made to clean, disinfect or sterilize these components.
    - Manufacturers instructions must be followed with regard to cleaning, disinfecting, and re-use of patient interfaces (masks.)
    - Only use bacterial/viral filters that are commercially available and designed for use with CPAP machines.
    - Only use those commercially available filters that do not require recalibration of the PAP device.
    - Do not submerge the Transcend Auto or power supply in liquid. Do not allow liquid or cleaning solution to enter the device.

Specification

Specifications

Transcend Auto

Auto - Titrating

Yes

Fixed Pressure

Yes
Hardware Features 

Dimensions (L x W x H)

15.5cm x 8.9cm x 7.1cm

Weight

426g

Sound Pressure Levels

26.6 dB
Operating Pressure (4 - 20 cmH2O)Yes

EZEX Pressure Relief (Settings 1,2,3)

Yes
Ramp (0 - 45min), adjustableYes
Automatic Altitude Adjustment - 2438m 
Power Supply 100-240 VAC, 50-60Hz, 19VDC, 2.6AmpYes
Air Filter: Disposable Filter MediaYes
Operating Range: 5degree - 35degreeC, 10%-80% relative humidity, non-condensingYes
Storage/Transport Range: 20degree - 60degreeC, 10%-90% relative humidity, non-condensingYes
EN60601-1: Class II Type BF, IP21 IEC 60601-1-2 EMC compatibilityYes
Compliance Data 
AHI &leak detectYes
Total therapy hoursYes
Therapy sessions: adjustable settings, 
default = 8 hours, 6 hours, and 4 hours
Yes
Total blower hoursYes
13 months daily compliance storageYes
Adjustable date range selectionYes
Summary data (unlimited, adjustable range)Yes
Detailed data (unlimited, adjustable range)Yes
Median snore index+
Median flow-limited breathing(%)+
Data Options 
Transfer via USB with Transcend SoftwareYes
Email-capable dataYes
TranSync wireless complianceYes
HumidificationYes
Transcend Heated Humidifier™Yes
Transcend Waterless Humidification™ 
System (HME)
Yes

Warranty

3 years warranty

Customer Reviews

Questions & Answers


 
 
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwheelchair.com

Close
;